- Pulse function: Significantly less rework thanks to low-spatter welding
- Better welding results thanks to safe ignition and stable arc
- Synergic function: pre-selecting wire Ø, material and gas, automatic calculation of wire tension and feed
- Precise setting of welding parameters via digital display with work memory
- Fewer errors therefore better quality
- La silenziosità le ventole in funzione dissipano bene il calore dalle unità e si traducono in a ciclo di lavoro elevato
- Arc-Force Control: Thanks to the internal monitoring of welding current and voltage, short circuits are resolved quickly and safely. This stabilizes the arc and the electrode can be processed without problems
- Less welding dust
- The filler wires can be easily soldered by simply reversing the polarity.
- Suitable for operation on a power generator
- Wide range of functions: MIG/MAG (Pulse, Dual Pulse, Synergic, Manual), TIG Lift Arc, E-Hand
- CRAFT-MIG 201P Pulse attrezzato con PFC (rifasamento), consente il miglior utilizzo anche su tamburi per cavi
- MB 25 welding torch, 3 m
- Gas pipe 12×6 mm, 4 m
- Argon/CO2 pressure reducer, large
- Rulli di avanzamento Ø 0,8 – 1,0 acciaio
- Elmetto per saldatura VarioProtect XXL-W
- Guanto per saldatura Taglia base L / Taglia 9
Features Inert gas pulse welder
Dimensions and weights | |
---|---|
Length (product) approx. | 580mm |
Width/depth (product) approx. | 230 mm |
Height (product) approx. | 400 mm |
Net weight approx. | 25kg |
Setting range | |
MIG/MAG setting range | 20 – 200 AD |
Work cycle | |
Duty cycle at Imax. 40°C | 40 |
Current at 60% DC 40°C | 165 |
Electrical data | |
Supply voltage | 110/230 |
Network frequency | 50/60 |
Basic functions | |
Method |
|
Sheet metal thicknesses |
|
Standards and certifications | |
Standard | EN 60 974-1; -10 |
EMC Class | TO |
Thread advancement | |
Wire feet unit | 4 |
Wire feed speed | 1.5 – 24 |
Energy consumption | |
Power factor | 0.99 cos phi |
Efficiency | 82,22 % |
Electrical connections | |
Open circuit voltage | MMA: 94,4 | TIG: 92,2 | MIG: 84,5 V |
Spiegazione Tensione a circuito aperto | Dati per tensione di collegamento 230 V |
Cooling | |
Cooling type | AF |