Farmer HCF Water Heater – Efficient Heating for Agricultural Environments
The Farmer HCF series water heaters are a high-quality heating solution, designed for agricultural environments such as greenhouses, stables, chicken and pig farms, and barns. Thanks to the GOLD EPOXY coating, these devices offer resistance even in aggressive environments, where high levels of acids, ammonia and dust are common. In addition, they guarantee greater product durability and reliability.
Environments of Use
The Farmer HCF series is particularly suitable for installation in agricultural spaces such as:
- Greenhouses
- Pig Farms
- Chicken coops
- Granaries
- Stables
Advantages of the Farmer HCF Air Heater
The Farmer HCF series air heaters offer numerous advantages thanks to the GOLD EPOXY antibacterial coating and other technical features. Among the main benefits we find:
- Long lasting: Device protection in harsh environments is guaranteed.
- Antibacterial protection: Prevents the growth of bacteria inside the device, improving safety.
- Corrosion resistance: Prevents mold growth and offers greater water resistance.
- Eco-friendly material: The EPP shell is lightweight, durable and 100% recyclable.
- Silent operation: Ensures comfort without sacrificing performance.
- Ease of installation: The compact and lightweight design makes assembly quick and easy.
Control and Operation
Farmer HCF air heaters are equipped with a complete control system. In addition, they can be combined with dedicated accessories from the HC series to optimize heating and reduce energy consumption. The three-speed fan (protection class IP 54) or single speed (protection class IP 66) ensures efficient heat distribution. The device complies with the European directive 2009/125/EC (ErP 2015), also ensuring compliance with environmental regulations.
Technical specifications
Characteristic | FARMER HCF IP54-3S | FARMER HCF IP66 |
---|---|---|
Product code | WHHCF47-3S-1765 | WHHCF53-1527 |
Nominal heating capacity [kW]* | 44.3 / 32.5 / 26.5 (3/2/1 stage) | 50.2 (single stage) |
Heating capacity range [kW] | 3,87 – 58,5 | 7,01 – 66,2 |
Maximum air flow [m³/h] | 4000 / 2400 / 1750 | 5000 |
Maximum isothermal flow radius [m] | 21 | 24 |
Number of tube rows [pieces] | 2 | 2 |
Water capacity [dm³] | 1,95 | 1,95 |
Maximum heating fluid temperature [°C] | 120 | 120 |
Maximum heating fluid pressure [MPa] | 1,6 | 1,6 |
Connection diameter [inches] | 3/4 | 3/4 |
Voltage/Frequency [V/Hz] | 230/50 | 230/50 |
Rated motor current [A] | 1.08 / 0.86 / 0.70 (3/2/1 stage) | 2,7 |
Rated engine speed [rpm] | 1360 / 1050 / 750 | 1335 |
Rated motor power [W] | 240 / 190 / 160 (3/2/1 stage) | 610 |
Motor IP protection class | 54 | 66 |
Net weight [kg] | 17,5 | 20 |
Noise [dB]** | 59 / 54 / 50 (3/2/1 stage) | 63 |
* – for parameters 90/70°C and inlet air temperature 0°C
** – maximum capacity refers to 120/90°C, 0°C inlet air temperature, 3rd stage // minimum capacity refers to 40/30°C, 20°C inlet air temperature, 1st stage
*** – maximum capacity refers to 120/90°C, 0°C inlet air temperature // minimum capacity refers to 40/30°C, 20°C inlet air temperature
**** – the measurement is taken at a distance of 5 metres from the device